Skip to content
A-101.3Reading Plans

What a Door and Window Schedule Tells You Before You Ask for a Quote

A door and window schedule links each plan tag to one row of details, so homeowners can confirm every quote prices the same openings before comparing totals.

Updated 5 min read4 sources cited
D01W012 040MARKW × HTYPED01870 × 2040SLIDINGD02920 × 2040POCKETW011800 × 1200AWNINGW02600 × 600SLIDINGW031200 × 900FIXED
SHEETA-101.3
DRAWINGDoor and window schedule
SCALENTS · illustrative

Key points

  • A door and window schedule gives each plan tag its own row of details, such as size, frame, glazing and energy values.
  • Every quote should list the same marks, from the same issued revision of the schedule, so the prices can be compared fairly.
  • Energy values for windows and doors should come from the NFRC label or product data, and missing values should be marked TBD rather than guessed.
  • Blank or TBD fields must be flagged, and suppliers should be asked to price against the same information or state their assumptions.
  • Egress, fire-rated and structural openings need confirmation from the local building authority or a licensed professional.

A door and window schedule is a table in the drawing set that gives each door and window tag on the plans its own row of details, such as size, frame, glazing and energy values. Homeowners can use it to check quotes by confirming that every supplier priced the same marks from the same issued revision. It does not replace the plans or the design team's review, and code, energy and safety values still need confirming with the local authority or a licensed professional.

What a door and window schedule is

A schedule links each plan tag, such as D-101 or W-204, to one row in a table. The row describes that opening: its size, type, frame, swing, glass, hardware, rating, energy data and remarks. Without a matching row, the person pricing the job has to guess.

The schedule may sit on a dedicated sheet or next to the plans. If you cannot find it, ask your design team where the schedule is kept in the drawing set.

Large projects usually split doors and windows into separate tables. Small projects may combine them in one table.

The column lists and checking steps in this article come from practical guidance on a commercial education site, ArchitectureCourses.org. That guidance is not a standard or a building code.

What the door section should show

A complete door row usually includes:

  • Mark, the tag that matches the plan.
  • Type, size (width, height and thickness), and door material or core.
  • Hand and swing, which show which way the door opens.
  • Frame and hardware set.
  • Fire or frame rating, where relevant.
  • Vision lite (any glass panel), accessibility flags and remarks.

What the window section should show

A complete window row usually includes:

  • Mark, type and operation (how the window opens).
  • Size and frame material.
  • Glazing, such as low-E, tempered or laminated.
  • U-factor and SHGC, the energy values explained below.
  • Egress note and safety glazing note.
  • Remarks.

Energy values should come from the NFRC label or the product data sheet. If a value is not yet known, the schedule should show TBD rather than an estimate from memory. In the United States, the ENERGY STAR climate zone affects which values to look for, so find that zone before comparing windows.

How to read an NFRC label in a schedule

The National Fenestration Rating Council (NFRC) is an independent, nonprofit certification body for the energy performance of windows, doors and skylights. It does not set minimum performance levels. The NFRC label is the tool for checking whether a specific window's energy values comply with the local energy code in the United States.

The window label carries five ratings. Their positions on the label are:

RatingPosition on the window labelWhat it measures
U-factorTop-left numberHeat transfer; lower means better insulation
SHGCTop-right numberSolar heat passing through; lower means less
VTMiddle or bottom row, leftVisible light; higher means more light
Air leakage (AL)Middle or bottom row, rightAir leakage per square foot of window area
Condensation resistanceBottom row, leftWater build-up; higher means less

The door label works differently. It shows one circled value for each door, based on its glass configuration, and that value is split into SHGC and U-factor.

The energy values apply to the specific product and glass configuration they describe.

The ratings also come with reference ranges that differ between sources. The EPA page gives a general U-factor range of 0.25 to 1.25, the NFRC page gives 0.20 to 1.20, and the NFRC buying guide shows 0.10 to 2.00 as typical. These are typical ranges, not pass or fail thresholds.

Sources also disagree on the role of air leakage (AL) in ENERGY STAR qualification. The EPA page says qualification is based on U-factor and SHGC only, and that most industry standards and building codes require AL of 0.3 cfm per square foot or less. The NFRC buying guide says an AL above 0.3 disqualifies a product from ENERGY STAR certification. This article does not settle that difference. The buying guide was last modified on 2024-05-07, so check the current ENERGY STAR criteria on the ENERGY STAR website before this article is published and before relying on any figure.

How to check that quotes cover the same openings

A schedule is most useful when it is used as a checklist for each quote. Work through these steps:

  1. Count the openings. Compare the mark list in each quote with the plan tag list. The count and the marks should match.
  2. Compare line by line. Check size, operation, frame, glazing and energy values for each mark.
  3. Flag gaps. Mark any TBD or blank field, and ask the supplier to price it or state an assumption in writing.
  4. Fix the revision. Ask each supplier to quote against the same issued schedule revision and to note any substitutions.

Marks should stay stable. Renumbering after pricing can break vendor quotes, hardware sets and field markups. When a tag changes, the revised tag should be clouded and logged.

The pre-issue checks for the design team are useful for homeowners to understand too. Every plan tag should appear once in the schedule, every schedule row should appear on a plan, elevation or detail, and the door and window counts should match the issued sheets.

Common gaps that cause price differences

Several gaps make quotes hard to compare:

  • Missing egress or safety glazing notes, so the glazing for an opening is not stated on the schedule.
  • Unclear hardware sets, where the schedule does not name the hardware clearly.
  • Blank or TBD values, which are not yet confirmed and must be flagged rather than assumed.

A weak schedule carries into the quote, the framing, the submittals and the inspection. Errors made at the quote stage can therefore lead to change orders later.

Questions to ask before requesting quotes

Before sending the schedule to suppliers, a homeowner can ask:

  • Is this the current issue of the schedule?
  • Are all marks on the plan listed in the schedule?
  • Are the energy values confirmed for my climate zone?
  • Are any fields still marked TBD, and who will confirm them?

When to involve a licensed professional

Code compliance, egress sizing, fire-rated openings and structural openings need review by a licensed professional or the local building authority. Homeowners should not try to judge structural, electrical or gas safety on their own from a schedule. The design team must check the schedule, and the energy, egress and fire values should be confirmed before construction.

The sources for this article are based in the United States. In the UK, Canada and Australia, schedule formats and energy rating systems differ, and units and labels used there were not verified here. Check local labels and sheet naming before relying on this article. Egress window sizes, safety glazing triggers and fire ratings vary by jurisdiction and code edition, and no current code numbers are given here.

Frequently asked questions

What information does a door and window schedule contain?

It contains one row for each plan tag, giving the opening's size, type, frame, glazing, hardware, ratings, energy data and remarks. Doors also list hand and swing, while windows list operation and egress or safety glazing notes. Missing energy values should be marked TBD rather than estimated from memory.

What should I do if a window's energy value is not known yet?

The schedule should show TBD rather than an estimate from memory. Ask each supplier to confirm the value from the NFRC label or product data for the specific product and glass. Quotes with different assumed values are not directly comparable.

Does the NFRC label set the minimum energy performance a window must reach?

No. The NFRC describes itself as an independent, nonprofit certification body and does not set minimum performance levels. The NFRC label is the tool for checking whether a window's energy values comply with the local energy code in the United States.

Can a schedule alone confirm that openings meet code?

No. A schedule can show what is planned, but code compliance, egress sizing, fire-rated openings and structural openings must be confirmed by the local building authority or a licensed professional. Homeowners should not judge these points on their own.

Sources

  1. Independently Tested and Certified Energy Performance — ENERGY STAR (U.S. EPA)energystar.gov
  2. Window Buying Guide - NFRC Consumer Guide to Windows — National Fenestration Rating Council (NFRC)efficientwindows.org
  3. How to Prepare a Door and Window Schedule for Construction — ArchitectureCourses.orgarchitecturecourses.org
  4. National Fenestration Rating Council - National Fenestration Rating Council — National Fenestration Rating Council (NFRC)nfrc.org

Keep reading